1,046 research outputs found

    Coal desulfurization by low temperature chlorinolysis, phase 2

    Get PDF
    An engineering scale reactor system was constructed and operated for the evaluation of five high sulfur bituminous coals obtained from Kentucky, Ohio, and Illinois. Forty-four test runs were conducted under conditions of 100 by 200 mesh coal,solvents - methlychloroform and water, 60 to 130 C, 0 to 60 psig, 45 to 90 minutes, and gaseous chlorine flow rate of up to 24 SCFH. Sulfur removals demonstrated for the five coals were: maximum total sulfur removal of 46 to 89% (4 of 5 coals with methylchloroform) and 0 to 24% with water. In addition, an integrated continuous flow mini-pilot plant was designed and constructed for a nominal coal rate of 2 kilograms/hour which will be operated as part of the follow-on program. Equipment flow sheets and design drawings are included for both the batch and continuous flow mini-pilot plants

    Making connections—strategies for single molecule fluorescence biophysics

    Get PDF
    Fluorescence spectroscopy and fluorescence microscopy carried out on the single molecule level are elegant methods to decipher complex biological systems; it can provide a wealth of information that frequently is obscured in the averaging of ensemble measurements. Fluorescence can be used to localise a molecule, study its binding with interaction partners and ligands, or to follow conformational changes in large multicomponent systems. Efficient labelling of proteins and nucleic acids is very important for any fluorescence method, and equally the development of novel fluorophores has been crucial in making biomolecules amenable to single molecule fluorescence methods. In this paper we review novel coupling strategies that permit site-specific and efficient labelling of proteins. Furthermore, we will discuss progressive single molecule approaches that allow the detection of individual molecules and biomolecular complexes even directly isolated from cellular extracts at much higher and much lower concentrations than has been possible so far

    Same same but different: the evolution of TBP in archaea and their eukaryotic offspring

    Get PDF
    Transcription factors TBP and TF(II)B assemble with RNA polymerase and the promoter DNA forming the initiation complex. Despite a high degree of conservation, the molecular binding mechanisms of archaeal and eukaryotic TBP and TF(II)B differ significantly. Based on recent biophysical data, we speculate how the mechanisms co-evolved with transcription regulation and TBP multiplicity

    Heat transfer and pressure drop in the main heat exchanger of a cryogenic mixed refrigerant cycle

    Get PDF
    Mixed refrigerant cycles (MRCs) offer a cost- and energy-efficient cooling method for the temperature range between 80 and 200 K. The performance of MRCs is substantially influenced by entropy production in the main heat exchanger. Due to the wide-boiling refrigerant mixtures applied in MRCs, a reliable design of the heat exchangers is challenging as two-phase heat transfer and pressure drop in both fluid streams must be considered simultaneously. This contribution presents a literature review on the boiling/condensation heat transfer and pressure drop of zeotropic mixtures at low temperatures. Based on this survey, suitable correlations for the design of MRC heat exchangers are identified

    History-sensitive versus future-sensitive approaches to security in distributed systems

    Full text link
    We consider the use of aspect-oriented techniques as a flexible way to deal with security policies in distributed systems. Recent work suggests to use aspects for analysing the future behaviour of programs and to make access control decisions based on this; this gives the flavour of dealing with information flow rather than mere access control. We show in this paper that it is beneficial to augment this approach with history-based components as is the traditional approach in reference monitor-based approaches to mandatory access control. Our developments are performed in an aspect-oriented coordination language aiming to describe the Bell-LaPadula policy as elegantly as possible. Furthermore, the resulting language has the capability of combining both history- and future-sensitive policies, providing even more flexibility and power.Comment: In Proceedings ICE 2010, arXiv:1010.530

    A non-interleaving process calculus for multi-party synchronisation

    Full text link
    We introduce the wire calculus. Its dynamic features are inspired by Milner's CCS: a unary prefix operation, binary choice and a standard recursion construct. Instead of an interleaving parallel composition operator there are operators for synchronisation along a common boundary and non-communicating parallel composition. The (operational) semantics is a labelled transition system obtained with SOS rules. Bisimilarity is a congruence with respect to the operators of the language. Quotienting terms by bisimilarity results in a compact closed category

    Histaminylation of glutamine residues is a novel posttranslational modification implicated in G-protein signaling

    Get PDF
    Posttranslational modifications (PTM) have been shown to be essential for protein function and signaling. Here we report the identification of a novel modification, protein transfer of histamine, and provide evidence for its function in G protein signaling. Histamine, known as neurotransmitter and mediator of the inflammatory response, was found incorporated into mastocytoma proteins. Histaminylation was dependent on transglutaminase II. Mass spectrometry confirmed histamine modification of the small and heterotrimeric G proteins Cdc42, Galphao1 and Galphaq. The modification was specific for glutamine residues in the catalytic core, and triggered their constitutive activation. TGM2-mediated histaminylation is thus a novel PTM that functions in G protein signaling. Protein alphamonoaminylations, thus including histaminylation, serotonylation, dopaminylation and norepinephrinylation, hence emerge as a novel class of regulatory PTMs

    Integrated Structure and Semantics for Reo Connectors and Petri Nets

    Full text link
    In this paper, we present an integrated structural and behavioral model of Reo connectors and Petri nets, allowing a direct comparison of the two concurrency models. For this purpose, we introduce a notion of connectors which consist of a number of interconnected, user-defined primitives with fixed behavior. While the structure of connectors resembles hypergraphs, their semantics is given in terms of so-called port automata. We define both models in a categorical setting where composition operations can be elegantly defined and integrated. Specifically, we formalize structural gluings of connectors as pushouts, and joins of port automata as pullbacks. We then define a semantical functor from the connector to the port automata category which preserves this composition. We further show how to encode Reo connectors and Petri nets into this model and indicate applications to dynamic reconfigurations modeled using double pushout graph transformation

    Experimental validation of a self-calibrating cryogenic mass flowmeter

    Get PDF
    The Karlsruhe Institute of Technology (KIT) and the WEKA AG jointly develop a commercial flowmeter for application in helium cryostats. The flowmeter functions according to a new thermal measurement principle that eliminates all systematic uncertainties and enables self-calibration during real operation. Ideally, the resulting uncertainty of the measured flow rate is only dependent on signal noises, which are typically very small with regard to the measured value. Under real operating conditions, cryoplant-dependent flow rate fluctuations induce an additional uncertainty, which follows from the sensitivity of the method. This paper presents experimental results with helium at temperatures between 30 and 70 K and flow rates in the range of 4 to 12 g/s. The experiments were carried out in a control cryostat of the 2 kW helium refrigerator of the TOSKA test facility at KIT. Inside the cryostat, the new flowmeter was installed in series with a Venturi tube that was used for reference measurements. The measurement results demonstrate the self-calibration capability during real cryoplant operation. The influences of temperature and flow rate fluctuations on the self-calibration uncertainty are discussed
    • …
    corecore